Studer XTM
Quick Overview
The 12V-XTM inverter/charger has a continuous power rating of 2kVA (XTM1500: 1.5kVA) up to an ambient temperature of 40°C. In addition, it can deliver 4.8kVA (XTM1500: 3.5kVA) for up to 5 seconds!
Thanks to this very high surge power capacity, it can supply without worries loads with a high start-up current
The battery charge current can be adjusted between 0 and 100Adc (XTM1500: 70A)
The 24V-XTM inverter/charger has a continuous power rating of 3kVA (XTM2000: 2kVA),
a 30 minute power rating of 3.5kVA (XTM2000: 2.4kVA),
and can deliver 9kVA (XTM2000: 6kVA) for up to 5 seconds
The battery charge current can be adjusted between 0 and 90Adc (XTM2000: 55A)
The 48V-XTM inverter/charger has a continuous power rating of 3.5kVA (XTM2600: 2kVA)
a 30 minute power rating of 4kVA (XTM2600: 2.6kVA)
and can deliver 10.5kVA (XTM2600: 6.5kVA) for up to 5 seconds
The battery charge current can be adjusted between 0 and 50Adc (XTM2600: 30A)
Options
RCC-02, RCC-03 remote control and programming center
battery status processor BSP
communication module Xcom-232i, equipped with a serial port RS-232
communication sets by internet with Xcom-LAN / Xcom-GSM
communication module Xcom-SMS
multi-protocol communication module Xcom-CAN
and more..
For more information, see Studer's Website

With its seemingly limitless programmable functions, the XTM offers unequalled flexibility compared to other products on the market.
The battery charge current can be adjusted. The factory default settings include a battery charge curve best suited for lead acid batteries with gelled electrolyte (GEL). This battery charge curve can be easily adapted to other types of batteries including OPzS, NiFe, Lithium and Redox Flow, to name but a few.
The transfer system is active when an AC power source (generator, public grid, shore power…) is available at the AC input of the Xtender. The transition between inverter and transfer mode is achieved without any power cut and allows up to 50Aac of current to pass through to the loads. Similarly, the transition between transfer and inverter mode is extremely fast (max 15ms), which makes the Xtender suitable for many UPS (uninterruptable power supply) applications.
The Smart-Boost function allows the Xtender to assist the AC source via the inverter function. This way, the currents from both sources (AC-in and inverter) are combined to deliver the energy required by big loads if the loads are more than the AC source can supply.
The injection function allows the Xtender to send energy to the grid. This function is especially useful in energy storage systems where either the excess energy is injected to the grid, or a specific current is injected at a specific time of the day.
The Xtender has two auxiliary contacts, configured by default for the automatic start of a generator and the alarm function.
The RCM-10 accessory offers a remote entry to control the inverter externally.
In addition, the Xtender can be equipped with a remote entry, which can be used to change functions or control the system externally.
Monitoring and control onsite or remotely is possible with the RCC-02/03 remote control or with the LAN, GSM or SMS interfaces. Detailed information on all Xtender accessories can be found on the corresponding section of the website.
The Xtender communication bus is shared with the MPPT solar charge controllers of the VarioTrack and VarioString series. Inverters and charge controllers are synchronized to ensure an optimum charge of the battery and use of available energy.
Features and performances
- True sine wave voltage
- Reliable and silent with any kind of load
- Outstanding overload capabilities
- Smart-Boost function for assistance to the source even with difficult loads
- Automatic reduction of peak loads (power shaving)
- Multi-stage programmable battery charger with PFC (Power Factor Correction)
- Stand-by level adjustable over a large range and from a very low threshold
- Ultra-fast transfer relay
- Control by digital signal processors (DSP)
- High efficiency
- 5-year warranty